Hasco Components International Corp.: A complete source for Reed Swiches, Electromechanical Relays and Magnets since 1976.
 
 
Home
About Hasco
Our Factory
Reed Relays
Electromechanical Relays
Latching Relays
Reed Switches/Magnets
Proximity Reed Switches
Catalog (PDF Download)
Relay Design
Request Quote
Links
Hasco Reps
Hasco Reps
Site Map
info@hascorelays.com
 

Latching Relays

The HAT Latching Relay is a heavy duty, single-coil latching relay, capable of switching 40 amps. The KLT Latching Relay is a highly reliable, miniature, single-coil latching relay; capable of switching up to 15 amps. These energy saving relays require no current to maintain contact closure, once the relay has been switched. To unlatch, simply reverse the polarity of the coil voltage. Save energy by implementing one of these latching relays into your system.

KLT-L SERIES      15A
FEATURES
Highly Reliable, low cost
Miniature size & large switch capacity up to 15A
High dielectric strength type
Fully Sealed
Green Energy Saving

CONTACT RATINGS
Contact Arrangement 1A. 1B. 1C
Contact Resistance 50mΩ (1A 24VDC)
Contact Material Silver tin oxide, gold flash
Contact Rating (Resistive) 3A 120VAC/28VDC
6A 120VAC/28VDC
12A 120VAC/28VDC
15A/120VAC
Max. Switching Voltage 277VAC/28VDC
Max. Switching Current 15A
Max. Switching Power 2770VA/300W
Mechanical Life 1x107 times
Electrical Life 1x105 times

CHARACTERISTICS
Insulation Resistance 100MΩ (at 500VDC)
Dielectric Strength Between coil & contacts 1500VAC 1min
Between open contacts 750VAC 1min
Reacting time (at noml. volt) 8ms max.
Resetting time (at noml. volt) 5ms max.
Humidity 45% ~ 85% RH
Ambient temperature -40°C ~ +85°C
Shock Resistance Functional 98m/s2
Destructive 980m/s2
Vibration resistance 10Hz to 55Hz 1.5mm DA
Unit weight Approx. 12g
Construction Wash tight, Flux proofed
Notes
1) The data shown above Notes are initial values.
2) Please find coil temperature curve in the charactic curved below

ORDERING INFORMATION
Ordering Information
COIL DATA at 20°C
Nominal Voltage VDC
Action/Reset Voltage VDC
Impulse Width ms
Coil Resistance Ω +/- 10%
5
4.0
100
31
6
4.8
100
45
9
7.2
100
100
12
9.6
100
180
24
19.2
100
720
48
38.4
100
2880

COIL
Coil Power 800mW

SAFETY APPROVAL RATINGS
UL&CUL 3A 120VAC/28VDC
6A 120VAC/28VDC
12A 120VAC/28VDC
15A/120VAC

OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: Inch (mm)

Outline Dimensions
PCB Layout
(Bottom View)
Outline Dimensions
PCB Layout (Bottom View)
Wiring Diagram (Bottom View)   1A 1B 1C
Straight Polarity
Reverse Polarity
Remark:
1) In case of no tolerance shown in outline dimension: outline dimension <1mm. tolerance should be +/-0.2mm; outline dimension >1mm and <5mm. tolerance should be +/-0.3mm; outline dimension >5mm. tolerance should be +/-0.4mm.
2) The tolerance without indicating for PCB layout is always +/-0.1mm.

Notice
1. Relay is on the “reset” or “set” status when being released from stock, with the considerationof shock risen from transit and relay mounting, relay would be changed to “set” or “reset” status, therefore, when application (connecting the power supply), pleasereset the relay to “set” or “reset” status on request.

2. In order to maintain “set” or “reset” status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than “set” or “reset” time. Do not energize voltage to “set” coil and “reset” coil simultaneously; and also long energized time (more than 1 min.) should be avoided.