| Hasco
Component's electromechanical relays range from less than
an amp to 80 amps. Hasco's relays are UL and CSA with some
TUV ratings. All relays have DC coils and many have an
AC coil. They come sealed for wave soldering and washing
thereby allowing the relays to be put on any assemble line.
There are surface mount low current relays available as
well.
HAT-905 SERIES HEAVY DUTY
SPDT 50A 2.5 mm CONTACT GAP
(preliminary specifications)
GENERAL SPECIFICATIONS
Contact Material:silver cadmium oxide with copper base
Max.continuous rated voltage:110% of nominal voltage.
Pull-In voltage:75% of nominal voltage.Min @ 25℃.
Drop-Out voltage:10% of nominal voltage. Min @ 25℃.
Contact Resistance:20 mΩ max.(Initial value)
Operating Temp:
Class B:-20℃ to 85℃
Class F:-20℃ to 105℃
Insulation Resist:DC 500V 10mΩ min.
Dielectric Strength:AC 4000V between contact and coil, frame and
contact, coil and frame one minute. AC 1500Vbetween contacts
one minute.
Operate Time: approx. 15 ms.
Release Time: approx. 10 ms.
Electrical Life:
10 × 10 operation min. for 30A resistive load (N.O.)
5 × 10 operations min. for 40A Resistive Load (N.O.)
Mechanical Life:10 × 10 operation min.
| DC COIL SPECIFICATIONS |
Nominal
Voltage
(VDC) |
Resistance
±10% @ 25℃
(Ohms) |
Coil Power
@ 25℃
(Watts) |
5 |
21 |
1.2W |
6 |
30 |
9 |
67.5 |
12 |
120 |
15 |
187.5 |
18 |
270 |
22 |
400 |
24 |
480 |
48 |
1920 |
110 |
10080 |
| AC COIL SPECIFICATIONS |
Nominal
Voltage
(at 25℃) |
Resistance
±10% @ 25℃
(Ohms) |
Coil Power
@ 25℃
(VA) |
12VAC |
27 |
Approx
2VA |
24VAC |
120 |
110VAC |
2,360 |
120VAC |
2,560 |
220VAC |
9,680 |
240VAC |
11,520 |
277VAC |
15,300 |
| MAXIMUM LOAD SPECIFICATIONS |
| Voltage |
Load Type |
SPNO |
SPNC |
| AC |
Resistive |
50A 120VAC |
30A 277VAC |
| Motor |
1HP 120VAC
2HP 277VAC |
1HP 120VAC
2HP 277VAC |
| General
Purpose |
50A 120VAC |
30A 277VAC |
| Ballast |
30A 120VAC
20A 227VAC |
30A 120VAC
20A 227VAC |
| Tungsten |
20A 120VAC |
10A 120VAC |
| DC |
Resistive |
50A 28VDC |
30A 28VDC |
ORDERING INFORMATION

WIRING DIAGRAMS

|